Preview

The EYE GLAZ

Advanced search
Open Access Open Access  Restricted Access Subscription or Fee Access

Incidence of complications associated with long- term wear of scleral rigid gas-permeable contact lenses in keratoconus

https://doi.org/10.33791/2222-4408-2025-3-197-203

Abstract

Background. Scleral rigid gas-permeable contact lenses (SCL) are the preferred method for visual correction in keratoconus (KC). However, complications associated with long-term scleral lens wear remain understudied in the scientific literature. Evaluating the incidence and spectrum of these complications is essential for optimizing patient management and enhancing the safety of scleral lens use in clinical practice. Purpose: To assess the frequency and types of complications associated with long-term scleral lens wear in patients with keratoconus. Materials and methods. The study included 50 patients (100 eyes) with bilateral stage I–IV keratoconus (Amsler–Krumeich classification). The mean age was 29.2 ± 4.3 years. All patients underwent standard ophthalmic examination prior to the selection of optical correction. Slit-lamp biomicroscopy and anterior segment optical coherence tomography (AS-OCT) were used to monitor and identify potential complications during scleral lens wear. Follow-up duration was 12 months. Results. A total of 86% of patients (n = 43) successfully adapted to scleral lenses, with a mean adaptation period of 20.4 ± 5.8 days and an average daily wear time of 11.2 ± 2.4 hours. The primary reasons for discontinuation (14%, n = 7) were handling difficulties (42.9%) and lens damage (28.6%). Among patients who continued lens wear, handling challenges were reported in 25.6%, conjunctival hyperemia in 16.3%, and vision blurring in 9.3%. At the 12-month follow-up, the following complications were observed: mechanical (conjunctival hyperemia – 16.3%, corneal epithelial abrasions – 2.3%), toxic-allergic (2.3%), and infectious (2.3%). No statistically significant correlation was found between daily wear time and complication rate (p = 0.371). However, prolonged adaptation (>20 days) significantly increased the risk of discontinuation (p = 0.002). Conclusion. Long-term scleral lens wear in keratoconus is associated with complications, primarily of mechanical origin. These findings highlight the need for regular follow-up to ensure timely detection and management of complications.

About the Authors

V. V. Averich
National Myopia Institute
Russian Federation

Veronika V. Averich, Cand. Sci. (Med.), Researcher, Department of Ocular Media Pathology, Senior Researcher, Department of Contact Vision Correction

7, Deguninskaya Str., Moscow, 127486



T. S. Mitichkina
Krasnov Research Institute of Eye Diseases
Russian Federation

Tatiana S. Mitichkina, Cand. Sci. (Med.), Senior Researcher, Department of Ocular Media Pathology

11A, B, Rossolimo Str., Moscow, 119021



A. Z. Abaev
Krasnov Research Institute of Eye Diseases
Russian Federation

Aslan Z. Abaev, Ophthalmologist, Postgraduate Student, Department of Ocular Media Pathology

11A, B, Rossolimo Str., Moscow, 119021



References

1. Fadel D, Kramer E. Potential contraindications to scleral lens wear. Cont Lens Anterior Eye. 2019;42(1):92–103. doi: 10.1016/j.clae.2018.10.024

2. DeLoss KS, Fatteh NH, Hood CT. Prosthetic Replacement of the Ocular Surface Ecosystem (PROSE) scleral device compared to keratoplasty for the treatment of corneal ectasia. Am J Ophthalmol. 2014;158(5):974–982. doi: 10.1016/j.ajo.2014.07.016

3. Koppen C, Kreps EO, Anthonissen L, et al. Scleral Lenses Reduce the Need for Corneal Transplants in Severe Keratoconus. Am J Ophthalmol. 2018;185:43–47. doi: 10.1016/j.ajo.2017.10.022

4. Nau CB, Harthan JS, Shorter ES, et al. Trends in Scleral Lens Fitting Practices: 2020 Scleral Lenses in Current Ophthalmic Practice Evaluation Survey. Eye Contact Lens. 2023;49(2):51– 55. doi: 10.1097/ICL.0000000000000960

5. Barnett M, Johns LK. Contemporary scleral lenses: theory and application (Vol. 4). Bentham Science Publishers, 2017. 510 p.

6. Barnett M, Courey C, Fadel D, et al. CLEAR – Scleral lenses. Cont Lens Anterior Eye. 2021;44(2):270–288. doi: 10.1016/j.clae.2021.02.001

7. Walker MK, Bergmanson JP, Miller WL, et al. Complications and fitting challenges associated with scleral contact lenses: A review. Cont Lens Anterior Eye. 2016;39(2):88–96. doi: 10.1016/j.clae.2015.08.003

8. Мягков АВ. Руководство по медицинской оптике. Часть 2. Контактная коррекция зрения. М.: Апрель; 2018:321. Myagkov AV. Guidelines for medical optics. Part 2. Contact vision correction. Moscow: April, 2018:321 (In Russ.).

9. Fuller DG, Wang Y. Safety and Efficacy of Scleral Lenses for Keratoconus. Optom Vis Sci. 2020;97(9):741–748. doi: 10.1097/OPX.0000000000001578

10. Lim CH, Stapleton F, Mehta JS: Review of contact lens-related complications. Eye Contact Lens. 2018;44 Suppl 2:S1–S10. doi: 10.1097/ICL.0000000000000481

11. Zainodin E, Najmee N, Hamzah F, Saliman N. Ocular complications in contact lens wear and the risk factors: A retrospective analysis. Environ-Behav Proc J. 2021;15:105–110. doi: 10.21834/ebpj.v6i17.2881

12. Waghmare SV, Jeria S. A Review of Contact Lens-Related Risk Factors and Complications. Cureus. 2022;14(10):e30118. doi: 10.7759/cureus.30118

13. Mondino BJ, Salamon SM, Zaidman GW. Allergic and to­ xic reactions of soft contact lens wearers. Surv Ophthalmol. 1982;26(6):337–344. doi: 10.1016/0039-6257(82)90126-6

14. Hotta F, Eguchi H, Nakayama-Imaohji H, et al. Microbiome analysis of contact lens care solutions and tear fluids of contact lens wearers: Possible involvement of streptococcal antigens in allergic symptoms related to contact lens wear. Int J Mol Med. 2020;46(4):1367–1376. doi: 10.3892/ijmm.2020.4678

15. Ortenberg I, Behrman S, Geraisy W, Barequet IS. Wearing time as a measure of success of scleral lenses for patients with irregular astigmatism. Eye Contact Lens. 2013;39(6):381–384. doi: 10.1097/ICL.0b013e31829e8faa


Review

For citations:


Averich V.V., Mitichkina T.S., Abaev A.Z. Incidence of complications associated with long- term wear of scleral rigid gas-permeable contact lenses in keratoconus. The EYE GLAZ. 2025;27(3):197-203. (In Russ.) https://doi.org/10.33791/2222-4408-2025-3-197-203

Views: 25


ISSN 2222-4408 (Print)
ISSN 2686-8083 (Online)