Preview

The EYE GLAZ

Advanced search
Open Access Open Access  Restricted Access Subscription or Fee Access

A clinical case of implantation of a customized toric multifocal IOL Lentis Mplus LU-313T

https://doi.org/10.33791/2222-4408-2025-3-231-236

Abstract

Background. Modern cataract surgery requires increasingly high standards to achieve excellent visual outcomes at all distances, with mandatory intraoperative correction of corneal astigmatism. In such cases, customized intraocular lenses (IOLs), calculated according to the patient’s specific biometric parameters, are used. This report presents a clinical case of implanting a customized toric multifocal IOL during cataract surgery in a patient with high axial myopia and concomitant corneal astigmatism. Case description. A 45-year-old male with complicated cataract, high axial myopia, and corneal astigmatism underwent phacoemulsification with implantation of a customized multifocal IOL (Lentis Mplus LU-313T). In addition to standard ophthalmological examinations, optical specular endothelial microscopy of the cornea, optical coherence tomography (OCT) of the retina, and Scheimpflug corneal densitometry were performed. Preoperative IOL power calculation was carried out using an online calculator based on IOLMaster and corneal topography data. Postoperatively, uncorrected visual acuity was 1.0 for distance, 0.4 at intermediate, and 0.5 at near. Discussion. Implantation of customized IOLs with rotationally asymmetric optics, with a +2.0 D addition in the dominant right eye (Lentis Mplus LU-313 MF-20T) and a +3.0 D addition in the nondominant left eye (Lentis Mplus LU-313 MF-30TX), eliminated the need for postoperative optical correction at different distances. High uncorrected visual acuity was achieved for distance, intermediate, and near vision. The absence of halo effect after surgery enabled the patient to drive comfortably, including in the evening and at night. Conclusion. This comprehensive surgical approach to treating complicated cataract in eyes with high myopia and corneal astigmatism provided complete visual rehabilitation and eliminated the need for additional optical correction.

About the Authors

P. A. Perevozchikov
Polyclinic “Novy Vzglyad”
Russian Federation

Petr A. Perevozchikov, Dr. Sci. (Med.), Deputy Chief Physician, Ophthalmologist

184 Svobody Str., Izhevsk, 426008



D. V. Peregudov
Visus Expert
Russian Federation

Dmitry V. Peregudov, Ophthalmologist

room 1, 29, Akademika Lavrentyeva Str., Dolgoprudny, Moscow Region, 141700



A. V. Solovey
Tri-Z
Russian Federation

Anna V. Solovey, Ophthalmologist

3 Borisa Galushkina Str., Moscow, 129301



References

1. Holladay JT. Exact toric intraocular lens calculations using currently available lens constants. Arch Ophthalmol. 2012;130:946–947. doi: 10.1001/archophthalmol.2011.1917

2. Hoffmann PC, Hutz WW. Analysis of biometry and prevalence data for corneal astigmatism in 23239 eyes. J Cataract Refract Surg. 2010;36:1479–1485. doi: 10.1016/j.jcrs.2010.02.025

3. Goggin M. Toric intraocular lenses: Evidence-based use. Clin Exp Ophthalmol. 2022;50(5):481–489. doi: 10.1111/ceo.14106r

4. Razmjoo H, Ghoreishi M, Milasi AM, Peyman A, Jafarzadeh Z, Mohammadinia M, Kobra N. Toric intraocular lens for astigmatism correction in cataract patients. Adv Biomed Res. 2017;6:123. doi: 10.4103/2277-9175.216777

5. Song JE, Khoramnia R, Son HS, Knorz MC, Choi CY. Comparison between bilateral implantation of a trifocal IOL and mixand-match implantation of a bifocal IOL and an extended depth of focus IOL. J Refract Surg. 2020;36(8):528–535. doi: 10.3928/1081597X-20200616-01

6. Schrecker J, Schröder S, Langenbucher A, Seitz B, Eppig T. Individually customized IOL versus standard spherical aberration-correcting IOL. J Refract Surg. 2019;35(9):565–574. doi: 10.3928/1081597X-20190814-02

7. Agresta B, Knorz MC, Donatti C, Jackson D. Visual acuity improvements after implantation of toric intraocular lenses in cataract patients with astigmatism: a systematic review. BMC Ophthalmol. 2012;12:41. doi: 10.1186/1471-2415-12-41

8. Zhong Y, Wang K, Yu X, Liu X, Yao K. Comparison of trifocal or hybrid multifocal-extended depth of focus intraocular lenses: a systematic review and meta-analysis. Sci Rep. 2021;11(1):6699. doi: 10.1038/s41598-021-86222-1


Review

For citations:


Perevozchikov P.A., Peregudov D.V., Solovey A.V. A clinical case of implantation of a customized toric multifocal IOL Lentis Mplus LU-313T. The EYE GLAZ. 2025;27(3):231-236. (In Russ.) https://doi.org/10.33791/2222-4408-2025-3-231-236

Views: 31


ISSN 2222-4408 (Print)
ISSN 2686-8083 (Online)