<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="review-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">glazmag</journal-id><journal-title-group><journal-title xml:lang="ru">The EYE ГЛАЗ</journal-title><trans-title-group xml:lang="en"><trans-title>The EYE GLAZ</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2222-4408</issn><issn pub-type="epub">2686-8083</issn><publisher><publisher-name>Академия медицинской оптики и оптометрии</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.33791/2222-4408-2026-3-265-269</article-id><article-id custom-type="elpub" pub-id-type="custom">glazmag-881</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ПРАКТИКУМ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>WORKSHOP</subject></subj-group></article-categories><title-group><article-title>Контактные линзы еженедельной замены PRECISION7: новый подход к повышению комплаенса пациентов</article-title><trans-title-group xml:lang="en"><trans-title>PRECISION7 contact lenses: fresh perspective on compliance</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Бенч</surname><given-names>Дж.</given-names></name><name name-style="western" xml:lang="en"><surname>Bench</surname><given-names>J.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Джонатон Бенч, директор по профессиональному обуче нию и развитию, международное направление</p><p>1214; Шмен-де-Бландонне, 8; Вернье; Женева</p><p>Для контактов: Ольга Захарова</p></bio><bio xml:lang="en"><p>Jonathon Bench, Director Professional Education and Development International</p><p>1214; Chemin de Blandonnet 8; Vernier; Geneva</p><p>For contacts: Olga Zakharova</p></bio><email xlink:type="simple">olga.zakharova@alcon.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Танг</surname><given-names>А.</given-names></name><name name-style="western" xml:lang="en"><surname>Tang</surname><given-names>A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Энсон Танг, директор по профессиональному обучению и развитию, регион Азия</p><p>1214; Шмен-де-Бландонне, 8; Вернье; Женева</p></bio><bio xml:lang="en"><p>Anson Tang, Director Professional Education and Development Asia</p><p>1214; Chemin de Blandonnet 8; Vernier; Geneva</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Фигейредо</surname><given-names>В.</given-names></name><name name-style="western" xml:lang="en"><surname>Figueiredo</surname><given-names>V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Вания Фигейредо, директор по профессиональному обучению и развитию, регион Европа</p><p>1214; Шмен-де-Бландонне, 8; Вернье; Женева</p></bio><bio xml:lang="en"><p>Vânia Figueiredo, Director Professional Education and Development Europe</p><p>1214; Chemin de Blandonnet 8; Vernier; Geneva</p></bio><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Алкон Менеджмент С.А. (Alcon Management S.A.)</institution><country>Швейцария</country></aff><aff xml:lang="en"><institution>Alcon Management S.A.</institution><country>Switzerland</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>25</day><month>09</month><year>2026</year></pub-date><volume>28</volume><issue>3</issue><fpage>265</fpage><lpage>269</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Академия медицинской оптики и оптометрии, 2026</copyright-statement><copyright-year>2026</copyright-year><copyright-holder xml:lang="ru">Академия медицинской оптики и оптометрии</copyright-holder><copyright-holder xml:lang="en">Академия медицинской оптики и оптометрии</copyright-holder><license xlink:href="https://www.theeyeglaz.com/jour/about/submissions#copyrightNotice" xlink:type="simple"><license-p>https://www.theeyeglaz.com/jour/about/submissions#copyrightNotice</license-p></license></permissions><self-uri xlink:href="https://www.theeyeglaz.com/jour/article/view/881">https://www.theeyeglaz.com/jour/article/view/881</self-uri><abstract><p>   В статье представлен обзор научных и клинических данных по новым силикон-гидрогелевым контактным линзам еженедельной замены PRECISION7. Рассмотрены особенности нового материала серафилкон А и технологии ACTIV-FLO, обеспечивающих длительное поддержание увлажненности поверхности линзы на протяжении всего 7-дневного периода использования. Представлены результаты лабораторных и клинических исследований, демонстрирующие сохранение комфорта, качества зрения и устойчивости к липидным отложениям при длительном ношении линз, включая использование цифровых устройств.</p><p>   Особое внимание уделено еженедельному режиму замены как новому подходу к линзам плановой замены, который может облегчать соблюдение рекомендованных сроков замены и способствовать повышению приверженности пациентов рекомендациям специалиста по контактной коррекции зрения.</p></abstract><trans-abstract xml:lang="en"><p>   This article provides an overview of the scientific and clinical evidence for the new PRECISION7 weekly replacement silicone hydrogel contact lenses. The properties of the novel serafilcon A material and the ACTIV-FLO technology, which maintains lens surface hydration throughout the 7-day replacement cycle, are described. Laboratory and clinical findings demonstrate sustained comfort, visual performance, and resistance to lipid deposition during prolonged wear, including under conditions of increased digital device use. The weekly replacement schedule is discussed as a novel reusable lens modality that may simplify adherence to recommended replacement schedules and support patient compliance with practitioner recommendations for contact lens wear.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>контактные линзы</kwd><kwd>силикон-гидрогелевые контактные линзы</kwd><kwd>контактные линзы еженедельной замены</kwd><kwd>PRECISION7</kwd><kwd>серафилкон А</kwd><kwd>ACTIV-FLO</kwd><kwd>комплаентность</kwd><kwd>режим замены контактных линз</kwd><kwd>комфорт ношения контактных линз</kwd><kwd>цифровая зрительная нагрузка</kwd><kwd>увлажненность поверхности линзы</kwd><kwd>контактная коррекция зрения</kwd></kwd-group><kwd-group xml:lang="en"><kwd>contact lenses</kwd><kwd>silicone hydrogel contact lenses</kwd><kwd>weekly replacement contact lenses</kwd><kwd>reusable contact lenses</kwd><kwd>PRECISION7</kwd><kwd>serafilcon A</kwd><kwd>ACTIV-FLO</kwd><kwd>patient compliance</kwd><kwd>replacement schedule adherence</kwd><kwd>contact lens comfort</kwd><kwd>digital eye strain</kwd><kwd>lens surface hydration</kwd><kwd>lipid deposition</kwd><kwd>vision correction</kwd></kwd-group><funding-group><funding-statement xml:lang="ru">Статья подготовлена при поддержке компании Alcon</funding-statement><funding-statement xml:lang="en">The authors received no financial support for the preparation of this article</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Morgan PB, Wood CA, Tranoudis IG, Efron N. International contact lens prescribing in 2021. Contact Lens Spectr. 2022;37:32–38.</mixed-citation><mixed-citation xml:lang="en">Morgan PB, Wood CA, Tranoudis IG, Efron N. International contact lens prescribing in 2021. Contact Lens Spectr. 2022;37:32–38.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Global CLI Annualized Q3 YTD 2022 Including Cosmetic. Анализ мирового рынка контактных линз по данным GfK. Данные исследования компании Alcon. 2022.</mixed-citation><mixed-citation xml:lang="en">Global CLI Annualized Q3 YTD 2022 Including Cosmetic. Анализ мирового рынка контактных линз по данным GfK. Данные исследования компании Alcon. 2022.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Dumbleton K, Woods C, Jones L, Fonn D, Sarwer DB. Patient and practitioner compliance with silicone hydrogel and daily disposable lens replacement in the United States. Eye Contact Lens. 2009;35(4):164–171. doi: 10.1097/ICL.0b013e3181ac4a8d</mixed-citation><mixed-citation xml:lang="en">Dumbleton K, Woods C, Jones L, Fonn D, Sarwer DB. Patient and practitioner compliance with silicone hydrogel and daily disposable lens replacement in the United States. Eye Contact Lens. 2009;35(4):164–171. doi: 10.1097/ICL.0b013e3181ac4a8d</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Global Strategic Insights 2023 (Ipsos Market Research). Опрос 500 оптометристов США, выполняющих подбор контактных линз. Данные исследования компании Alcon. 2023.</mixed-citation><mixed-citation xml:lang="en">Global Strategic Insights 2023 (Ipsos Market Research). Опрос 500 оптометристов США, выполняющих подбор контактных линз. Данные исследования компании Alcon. 2023.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Zheng Y, Dou J, Wang Y, et al. Sustained release of a polymeric wetting agent from a silicone hydrogel contact lens material. ACS Omega. 2022;7(33):29223–29230. doi: 10.1021/acsomega.2c03310</mixed-citation><mixed-citation xml:lang="en">Zheng Y, Dou J, Wang Y, et al. Sustained release of a polymeric wetting agent from a silicone hydrogel contact lens material. ACS Omega. 2022;7(33):29223–29230. doi: 10.1021/acsomega.2c03310</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Phan CM, Chan VW, Dolle E, et al. Evaluating the in vitro wettability and coefficient of friction of novel and contemporary reusable silicone hydrogel contact lens materials using an in vitro blink model. Cont Lens Anterior Eye. 2024;47(2):102129. doi: 10.1016/j.clae.2024.102129</mixed-citation><mixed-citation xml:lang="en">Phan CM, Chan VW, Dolle E, et al. Evaluating the in vitro wettability and coefficient of friction of novel and contemporary reusable silicone hydrogel contact lens materials using an in vitro blink model. Cont Lens Anterior Eye. 2024;47(2):102129. doi: 10.1016/j.clae.2024.102129</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Dumbleton KA, Guillon M, Theodoratos P, Patel T. Diurnal variation in comfort in contact lens and non-contact lens wearers. Optom Vis Sci. 2016;93(8):820–827. doi: 10.1097/OPX.0000000000000920</mixed-citation><mixed-citation xml:lang="en">Dumbleton KA, Guillon M, Theodoratos P, Patel T. Diurnal variation in comfort in contact lens and non-contact lens wearers. Optom Vis Sci. 2016;93(8):820–827. doi: 10.1097/OPX.0000000000000920</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Lievens C, Perkins A, Rayborn E, et al. Real-time changes in the comfort of a toric monthly soft contact lens over a long day of wear. Clin Optom. 2024;16:317–325. doi: 10.2147/OPTO.S490934. 9.</mixed-citation><mixed-citation xml:lang="en">Lievens C, Perkins A, Rayborn E, et al. Real-time changes in the comfort of a toric monthly soft contact lens over a long day of wear. Clin Optom. 2024;16:317–325. doi: 10.2147/OPTO.S490934. 9.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Walther H, Lorentz H, Heynen M, Lay L, Jones LW. Factors that influence in vitro cholesterol deposition on contact lenses. Optom Vis Sci. 2013;90(10):1057–1065. doi: 10.1097/OPX.0000000000000022</mixed-citation><mixed-citation xml:lang="en">Walther H, Lorentz H, Heynen M, Lay L, Jones LW. Factors that influence in vitro cholesterol deposition on contact lenses. Optom Vis Sci. 2013;90(10):1057–1065. doi: 10.1097/OPX.0000000000000022</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Walther H, Subbaraman L, Jones LW. In vitro cholesterol deposition on daily disposable contact lens materials. Optom Vis Sci. 2016;93(1):36–41. doi: 10.1097/OPX.0000000000000749</mixed-citation><mixed-citation xml:lang="en">Walther H, Subbaraman L, Jones LW. In vitro cholesterol deposition on daily disposable contact lens materials. Optom Vis Sci. 2016;93(1):36–41. doi: 10.1097/OPX.0000000000000749</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Terry RL, Schnider CM, Holden BA, et al. CCLRU standards for success of daily and extended wear contact lenses. Optom Vis Sci. 1993;70(3):234. doi: 10.1097/00006324-199303000-00011</mixed-citation><mixed-citation xml:lang="en">Terry RL, Schnider CM, Holden BA, et al. CCLRU standards for success of daily and extended wear contact lenses. Optom Vis Sci. 1993;70(3):234. doi: 10.1097/00006324-199303000-00011</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Craig JP, Willcox MDP, Argueso P, et al. The TFOS International Workshop on Contact Lens Discomfort: report of the contact lens interactions with the tear film subcommittee. Invest Ophthalmol Vis Sci. 2013;54(11):TFOS123–TFOS156. doi: 10.1167/iovs.13-13235</mixed-citation><mixed-citation xml:lang="en">Craig JP, Willcox MDP, Argueso P, et al. The TFOS International Workshop on Contact Lens Discomfort: report of the contact lens interactions with the tear film subcommittee. Invest Ophthalmol Vis Sci. 2013;54(11):TFOS123–TFOS156. doi: 10.1167/iovs.13-13235</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Guillon M, Dumbleton KA, Theodoratos P, Wong S, Patel K, Patel T. Association between contact lens discomfort and prelens tear film kinetics. Optom Vis Sci. 2016;93(8):881–891. doi: 10.1097/OPX.0000000000000866</mixed-citation><mixed-citation xml:lang="en">Guillon M, Dumbleton KA, Theodoratos P, Wong S, Patel K, Patel T. Association between contact lens discomfort and prelens tear film kinetics. Optom Vis Sci. 2016;93(8):881–891. doi: 10.1097/OPX.0000000000000866</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Проспективное рандомизированное двойное слепое перекрестное клиническое исследование контактных линз PRECISION7® и ACUVUE OASYS® 2-Week, проведенное в США (n = 181). Данные исследования компании Alcon. 2023.</mixed-citation><mixed-citation xml:lang="en">Проспективное рандомизированное двойное слепое перекрестное клиническое исследование контактных линз PRECISION7® и ACUVUE OASYS® 2-Week, проведенное в США (n = 181). Данные исследования компании Alcon. 2023.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Лабораторная оценка липидных отложений на контактных линзах. Данные исследования компании Alcon. 2023.</mixed-citation><mixed-citation xml:lang="en">Лабораторная оценка липидных отложений на контактных линзах. Данные исследования компании Alcon. 2023.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
