<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">glazmag</journal-id><journal-title-group><journal-title xml:lang="ru">The EYE ГЛАЗ</journal-title><trans-title-group xml:lang="en"><trans-title>The EYE GLAZ</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2222-4408</issn><issn pub-type="epub">2686-8083</issn><publisher><publisher-name>Академия медицинской оптики и оптометрии</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">glazmag-484</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Статьи</subject></subj-group></article-categories><title-group><article-title>Клинические результаты имплантации интраокулярной линзы с расширенной глубиной фокуса Tecnis Symfony</article-title><trans-title-group xml:lang="en"><trans-title></trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-6105-1632</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Анисимова</surname><given-names>Н. С.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Анисимова Наталья Сергеевна, кандидат медицинских наук, главный врач; ассистент кафедры глазных болезней</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-1922-4939</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Анисимов</surname><given-names>С. И.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Анисимов Сергей Игоревич, доктор медицинских наук, научный директор; профессор кафедры глазных болезней</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-9289-3920</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Данильченко</surname><given-names>М. И.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Данильченко Марина Ивановна, врач-офтальмолог; аспирант кафедры глазных болезней</p></bio><email xlink:type="simple">eyedocmk@gmail.com</email><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Глазной центр «Восток-Прозрение»; ФГБОУ ВО «Московский государственный медико-стоматологический университет им. А.И. Евдокимова» Минздрава России</institution><country>Russian Federation</country></aff><aff xml:lang="ru" id="aff-2"><institution>ФГБОУ ВО «Московский государственный медико-стоматологический университет им. А.И. Евдокимова» Минздрава России</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>2022</year></pub-date><pub-date pub-type="epub"><day>08</day><month>12</month><year>2023</year></pub-date><volume>0</volume><issue>0</issue><issue-title>Pre-Publication</issue-title><elocation-id>484</elocation-id><permissions><copyright-statement>Copyright &amp;#x00A9; Академия медицинской оптики и оптометрии, 2022</copyright-statement><copyright-year>2022</copyright-year><copyright-holder xml:lang="ru">Академия медицинской оптики и оптометрии</copyright-holder><copyright-holder xml:lang="en">Академия медицинской оптики и оптометрии</copyright-holder><license xlink:href="https://www.theeyeglaz.com/jour/about/submissions#copyrightNotice" xlink:type="simple"><license-p>https://www.theeyeglaz.com/jour/about/submissions#copyrightNotice</license-p></license></permissions><self-uri xlink:href="https://www.theeyeglaz.com/jour/article/view/484">https://www.theeyeglaz.com/jour/article/view/484</self-uri><abstract><sec><title>Актуальность</title><p>Актуальность. Одни из самых современных интраокулярных линз (ИОЛ) – это ИОЛ с расширенной глубиной фокуса. Такие линзы позволяют снизить зависимость от очков, распределяя световую энергию на дальний фокус и фокус средней дистанции без потери качества зрения. Исследования, в которых проводится анализ результатов имплантации данного типа линз, немногочисленны.</p></sec><sec><title>Цель</title><p>Цель: оценить клинические результаты имплантации модели ИОЛ Tecnis Symfony с увеличенной глубиной фокуса. Материалы и методы. В проспективное исследование был включен 61 пациент (79 глаз) в возрасте от 18 до 86 лет. Пациентам после операции факоэмульсификации имплантировали ИОЛ Tecni s Symfony (США). Исследование проводили с ноября 2020 года по ноябрь 2022 года. В работе исследовали некорригированную и корригированную остроту зрения вдаль (НКОЗ и КОЗ) и вблизи на расстоянии 30, 40 и 50 см, монокулярную кривую дефокусировки, а также данные рефракции в ранний послеоперационный период. При расчете ИОЛ целевой сферический эквивалент составлял –0,35 ± 0,11 дптр.</p></sec><sec><title>Результаты</title><p>Результаты. Через 3 месяца после операции в 82,4 % случаев НКОЗ вдаль, а также в 100 % – КОЗ вдаль и в 50 % – НКОЗ вблизи составили 0,7 и лучше. Через 3 месяца после операции НКОЗ вдаль и вблизи на расстоянии 40 см составила в среднем 0,85 ± 0,15 и 0,69 ± 0,18 соответственно. КОЗ вдаль и вблизи на 40 см составила 0,98 ± 0,04 и 0,8± 0,14 соответственно. В 85,7 % случаев получили остроту зрения не менее 0,5 при глубине дефокуса от 1,5 до –1,5 дптр.</p></sec><sec><title>Заключение</title><p>Заключение. Имплантация ИОЛ Tecnis Symfony при коррекции афакии в ходе операции по удалению катаракты обеспечивает хорошие функциональные данные остроты зрения вдаль и на среднем расстоянии. Острота зрения вблизи является удовлетворительной и может быть улучшена с помощью микромонозрения.</p></sec></abstract></article-meta></front><back><ref-list><title>References</title></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
