<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">glazmag</journal-id><journal-title-group><journal-title xml:lang="ru">The EYE ГЛАЗ</journal-title><trans-title-group xml:lang="en"><trans-title>The EYE GLAZ</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2222-4408</issn><issn pub-type="epub">2686-8083</issn><publisher><publisher-name>Академия медицинской оптики и оптометрии</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">glazmag-482</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Статьи</subject></subj-group></article-categories><title-group><article-title>Способ определения внутриглазного давления по данным кератотопографических показателей</article-title><trans-title-group xml:lang="en"><trans-title></trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-8216-5025</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Ахметов</surname><given-names>Н. Р.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Ахметов Наиль Равилевич, очный аспирант кафедры офтальмологии; врач-офтальмолог </p></bio><email xlink:type="simple">ahmetovn17@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-0863-7762</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Самойлов</surname><given-names>А. Н.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Самойлов Александр Николаевич, доктор медицинских наук, профессор, заведующий кафедрой офтальмологии; врач-офтальмолог и главный специалист </p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-0549-783X</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Усов</surname><given-names>В. А.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Усов Виктор Алексеевич, кандидат медицинских наук, ассистент кафедры офтальмологии </p></bio><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>ФГБОУ ВО «Казанский государственный медицинский университет» Минздрава России; ГАУЗ «Республиканская клиническая офтальмологическая больница Министерства здравоохранения Республики Татарстан имени профессора Е.В. Адамюка»</institution><country>Russian Federation</country></aff><aff xml:lang="ru" id="aff-2"><institution>ФГБОУ ВО «Казанский государственный медицинский университет» Минздрава России</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>2022</year></pub-date><pub-date pub-type="epub"><day>08</day><month>12</month><year>2023</year></pub-date><volume>0</volume><issue>0</issue><issue-title>Pre-Publication</issue-title><elocation-id>482</elocation-id><permissions><copyright-statement>Copyright &amp;#x00A9; Академия медицинской оптики и оптометрии, 2022</copyright-statement><copyright-year>2022</copyright-year><copyright-holder xml:lang="ru">Академия медицинской оптики и оптометрии</copyright-holder><copyright-holder xml:lang="en">Академия медицинской оптики и оптометрии</copyright-holder><license xlink:href="https://www.theeyeglaz.com/jour/about/submissions#copyrightNotice" xlink:type="simple"><license-p>https://www.theeyeglaz.com/jour/about/submissions#copyrightNotice</license-p></license></permissions><self-uri xlink:href="https://www.theeyeglaz.com/jour/article/view/482">https://www.theeyeglaz.com/jour/article/view/482</self-uri><abstract><sec><title>Введение</title><p>Введение. В большинстве стран мира остаются популярными аппланационные тонометры, такие как тонометр Маклакова и тонометр Гольдмана. При измерении ими офтальмотонуса получают значения внутриглазного давления (ВГД) опосредованно через роговицу, что, безусловно, вносит погрешности в результаты. Создание методик определения ВГД, отличных от ныне существующих, является актуальной задачей.</p><p>Цель – создать новую методику определения внутриглазного давления без проведения тонометрии, опираясь на показатели индивидуального профиля роговицы с ее параметрами, индексами и данными авторефрактометрии.</p></sec><sec><title>Материалы и методы</title><p>Материалы и методы. Проведен статистический анализ показателей кератотопографа (ALLEGRO Oculyzer, WaveLight Oculyzer II), данных авторефрактометра (аппарата TONOREF Nidek) и результатов измерений внутриглазного давления с использованием тонометра Маклакова (НГм2-«ОФТ-П») у 500 пациентов (1000 глаз). Среди выборочной совокупности были пациенты как с эмметропической рефракцией – 8 глаз (0,8 %), так и с аномалиями рефракции – 992 глаза (99,2 %), из которых 978 глаз (97,8 %) имели миопическую рефракцию, 14 (1,4 %) – простой миопический астигматизм. 889 глаз (88,9 %) сочетали миопическую рефракцию с миопическим астигматизмом.</p></sec><sec><title>Результаты</title><p>Результаты. На основании проведенного анализа кератотопографических показателей, значений авторефрактометрии и тонометрического ВГД нами создана новая методика определения внутриглазного давления без проведения тонометрии, представленная в виде математической модели: Pt keratotopographic = 61,9–0,06 × SPH – 2,39 × Rf + 0,64 × Rmin – 0,15 × log2 (IVA) – 31,9 × CKI – 0,006 × Thickness.</p></sec><sec><title>Заключение</title><p>Заключение. Исходя из полученных результатов, выведена математическая модель для расчета ВГД без физического взаимодействия с глазом. Созданную формулу можно использовать в тех случаях, когда применение тонометрии невозможно.</p></sec></abstract></article-meta></front><back><ref-list><title>References</title></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
