<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">glazmag</journal-id><journal-title-group><journal-title xml:lang="ru">The EYE ГЛАЗ</journal-title><trans-title-group xml:lang="en"><trans-title>The EYE GLAZ</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2222-4408</issn><issn pub-type="epub">2686-8083</issn><publisher><publisher-name>Академия медицинской оптики и оптометрии</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.33791/2222-4408-2021-1-29-39</article-id><article-id custom-type="elpub" pub-id-type="custom">glazmag-228</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОБЗОР ЛИТЕРАТУРЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>REVIEWS</subject></subj-group></article-categories><title-group><article-title>Уход за контактными линзами: прошлое, настоящее и будущее (обзор литературы)</article-title><trans-title-group xml:lang="en"><trans-title>Contact Lens Care: Past, Present and Future (a Literature Review)</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Маркосян</surname><given-names>А. Г.</given-names></name><name name-style="western" xml:lang="en"><surname>Markosyan</surname><given-names>A. G.</given-names></name></name-alternatives><bio xml:lang="ru"><p> Маркосян Армида Григорьевна, кандидат медицинских наук, врач-офтальмолог клиники, врач-офтальмолог </p><p>121099, Москва, 1-й Смоленский переулок, д.7125047,  Москва, 3-я Тверская-Ямская ул., д.12, стр.1</p></bio><bio xml:lang="en"><p> Armida G. Markosyan, PhD (Med.), Ophthalmologist </p><p>7, 1st Smolensky pereulok, Moscow, 121099</p><p>12, bld. 1, 3-ya Tverskaya-Yamskaya Str., Moscow, 125047</p></bio><email xlink:type="simple">markosyan_armida@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>МЦ OOO «ГВМ Интернешионал»; ООО «ОптикалНэт»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>“GVM International” Medical Center; “OpticalNet” Medical Center</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2021</year></pub-date><pub-date pub-type="epub"><day>23</day><month>03</month><year>2021</year></pub-date><volume>23</volume><issue>1</issue><fpage>29</fpage><lpage>39</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Академия медицинской оптики и оптометрии, 2021</copyright-statement><copyright-year>2021</copyright-year><copyright-holder xml:lang="ru">Академия медицинской оптики и оптометрии</copyright-holder><copyright-holder xml:lang="en">Академия медицинской оптики и оптометрии</copyright-holder><license xlink:href="https://www.theeyeglaz.com/jour/about/submissions#copyrightNotice" xlink:type="simple"><license-p>https://www.theeyeglaz.com/jour/about/submissions#copyrightNotice</license-p></license></permissions><self-uri xlink:href="https://www.theeyeglaz.com/jour/article/view/228">https://www.theeyeglaz.com/jour/article/view/228</self-uri><abstract><sec><title>Введение</title><p>Введение. Количество пользователей контактных линз продолжает расти, превышая общее число 125 миллионов человек в мире. Тенденцией современной контактной коррекции зрения является создание индивидуальных средств коррекции зрения и специальных средств по уходу за линзами, максимально удовлетворяющих потребностям пациентов всех возрастных групп.</p></sec><sec><title>Цель</title><p>Цель. Изучить эволюцию средств по уходу за контактными линзами, их свойства, характеристики состава, надежность очистки и дезинфекции, совместимость с материалами контактных линз, а также влияние растворов по уходу за контактными линзами на микробиом глаза на основе обзора данных литературы.</p><p>Материал и методы исследования. Проведен анализ публикаций на таких ресурсах, как Pubmed, BCLA, Elibrary, Elsevier, Medline за последние 20 лет, проанализировано 48 источников литературы. Результаты . Анализ литературных источников показал, что эволюция как контактных линз, так и средств ухода за ними не снизила, а ужесточила систему контроля за безопасностью ношения. Изучены не только состав и характеристики каждого компонента многофункциональных систем для ухода и дезинфекции контактных линз, но и свойства микробиома глаза и его изменение при ношении контактных линз. При прочих равных показателях отмечено, что пероксидные системы для ухода за контактными линзами по сравнению с многофункциональными растворами обеспечивают более надежную защиту от загрязнения всех типов линз, а также лучше дезинфицируют линзы, защищая глаз от возможных микробных, токсических и аллергических осложнений. Также проанализировано поведение пациентов методом анкетирования и выявлены их «страхи» по ношению КЛ и уходу за ними в период пандемии COVID-19.</p></sec><sec><title>Выводы</title><p>Выводы . Выбор средства по уходу за линзами для пациента должен быть одобрен специалистами по контактной коррекции зрения и офтальмологами. Средства по уходу за контактными линзами должны обеспечивать идеальную очистку линз, максимальную дезинфекцию, увлажнение и быть совместимыми с  материалом линз. Их нужно подбирать с  учетом индивидуальных особенностей поверхности глаза, образа жизни и состояния здоровья пациента. Необходимо постоянно просвещать и информировать пациентов о важности средств по уходу за линзами для здоровья глаз, а также уделять особое внимание уходу в период пандемии для безопасного ношения контактных линз.</p></sec></abstract><trans-abstract xml:lang="en"><sec><title>Introduction</title><p>Introduction. The number of contact lens users continues to increase, exceeding the total of more than 125 million people in the world. The trend of modern vision correction with contact lenses is the creation of customized contact lenses and specialty lens care products that better meet the needs of patients of all age groups.</p></sec><sec><title>Purpose</title><p>Purpose. To study the evolution of contact lens care products, their properties, composition characteristics, reliability of cleaning and disinfection, advantages and disadvantages of multifunctional solutions and peroxide systems, compatibility with contact lens materials as well as the effct of contact lens care solutions on the eye microbiome based on a literature data review.</p></sec><sec><title>Material and methods</title><p>Material and methods. The analysis of scientifi publications available on Pubmed, BCLA, Elibrary, Elsevier and Medline for the last 20 years was carried out; 48 sources of literature were analyzed.</p></sec><sec><title>Results</title><p>Results. The analysis of literature has shown that the evolution of both contact lenses and contact lens care products has tightened the control over the safety of wearing. We have studied not only the composition and characteristics of each component of contact lens care and disinfection systems, but also the properties of the eye microbiome and its changes whilst wearing contact lenses. It is noted that under otherwise equal conditions, peroxide systems for contact lens care provide more reliable protection against contamination of all types of lenses, as well as ensure a better disinfection, protecting the eye from possible microbial, toxic and allergic complications. We also analyzed patients’ behavior and identifid their concerns during the COVID-19 pandemic.</p></sec><sec><title>Conclusion</title><p>Conclusion. The patient’s choice of a lens care product must be approved by contact lens specialist and ophthalmologist. Contact lens care products should ensure perfect cleaning, maximum disinfection, hydration and be compatible with lens materials; they should be selected taking into account the patient-specifi characteristics of the ocular surface, lifestyle and health condition. It is necessary to continuously educate and inform patients about the importance of lens care products, and special attention should be paid to care during a pandemic for the safe wearing of CL.</p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>многофункциональные растворы</kwd><kwd>уход за контактными линзами</kwd><kwd>пероксидные системы</kwd><kwd>отложения на линзах</kwd><kwd>контейнер для хранения линз</kwd><kwd>микробиом глаза</kwd><kwd>осложнения контактной коррекции</kwd><kwd>COVID-19</kwd></kwd-group><kwd-group xml:lang="en"><kwd>contact lens cleaning solution</kwd><kwd>contact lens care</kwd><kwd>peroxide systems</kwd><kwd>lens deposits</kwd><kwd>contact lens case</kwd><kwd>eye microbiome</kwd><kwd>contact lens vision correction</kwd><kwd>COVID-19</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Киваев A.A., Шапиро Б.И. Контактная коррекция зрения. ЛДМ Сервис; 2000:224.</mixed-citation><mixed-citation xml:lang="en">Kivaev A.A., Shapiro E.I.. Contact vision correction. LDM Service, 2000:224. (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Мягков А.В. Руководство по медицинской оптике. Часть 2. Контактная коррекция зрения. Апрель, Москва. 2018:321.</mixed-citation><mixed-citation xml:lang="en">Myagkov А.V. Medical optics guide. Part 2 Contact correction of vision. April, Moscow. 2018:321. (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Бажина А.А. Новые многофункциональные растворы для ухода за контактными линзами: Автореф. дис. … канд. фарм. наук. Пятигорск; 2011:24.</mixed-citation><mixed-citation xml:lang="en">Bazhina А.А. New multifunctional solutions for lens care, autoref. dis., 2011:24.(In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Morgan P.B., Woods C.A., Tranoudis I.G. et al. International Contact Lens Prescribing in 2018. Contact Lens Spectrum. 2019;34(2):26–32.</mixed-citation><mixed-citation xml:lang="en">Morgan  P.B.,  Woods  C.A.,  Tranoudis  I.G. et  al.  International  Contact Lens Prescribing  in 2018.  Contact Lens Spectrum. 2019;34(2):26–32.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Epstein A.A. Keeping Lenses CleanCleaning is the second key to unlocking the science of comfort and ensuring that your patients will be successful contact lens wearers. Contact Lens Spectrum. 2009;1(4), https://www.clspectrum.com/supplements/2009/april-2009/the-science-of-comfort/keeping-lenses-clean</mixed-citation><mixed-citation xml:lang="en">Epstein A.A.  Keeping Lenses CleanCleaning is the second key to unlocking the science of comfort and ensuring that your patients will be successful contact lens wearers. Contact Lens Spectrum. 2009;1(4), https://www.clspectrum.com/supplements/2009/april-2009/the-science-of-comfort/keeping-lenses-clean</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Dalton K., Subbaraman L.N., Rogers R. et al. Physical properties of soft contact lens solutions. Optom. Vis. Sci. 2008;85(2):122–128. https://doi.org/10.1097/OPX.0b013e318162261e</mixed-citation><mixed-citation xml:lang="en">Dalton K., Subbaraman L.N., Rogers R. et al. Physical properties of soft contact lens solutions. Optom. Vis. Sci. 2008;85(2):122–128. https://doi.org/10.1097/OPX.0b013e318162261e</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">SulleyA.,Young G., Hunt C., McCready S., Targett M.-Th., Craven R. Retention Rates in New Contact Lens Wearers Multicenter Study. Eye Contact Lens. 2018;44(9(1)):273–282. https://doi.org/10.1097/ICL.0000000000000402</mixed-citation><mixed-citation xml:lang="en">SulleyA.,Young G., Hunt C., McCready S., Targett M.-Th., Craven R. Retention Rates in New Contact Lens Wearers Multicenter Study.  Eye Contact Lens.  2018;44(9(1)):273–282. https://doi.org/10.1097/ICL.0000000000000402</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Wu Y.T., Wilcox M., Zhu H. et al. Contact lens hygiene compliance and lens case contamination – a Review. Anterior Eye. 2015;38(5(Oct.)):307–16. https://doi.org/10.1016/j.clae.2015.04.007.</mixed-citation><mixed-citation xml:lang="en">Wu Y.T., Wilcox M., Zhu H. et al. Contact lens hygiene compliance and lens case contamination – a Review. Anterior Eye. 2015;38(5(Oct.)):307–16. https://doi.org/10.1016/j.clae.2015.04.00</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Phillips A.J., Speedwel L. Contact Lenses (Sixth Edition). Elsevier, London; 2018:592.</mixed-citation><mixed-citation xml:lang="en">Phillips A.J., Speedwel L. Contact Lenses (Sixth Edition). Elsevier, London; 2018:592.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Contact Lens Solutions – Global Market Trajectory &amp; Analytics. ID: 5028137 Report. Global Industry Analysts, Inc. 2020;September:367.</mixed-citation><mixed-citation xml:lang="en">Contact Lens Solutions – Global Market Trajectory &amp; Analytics. ID: 5028137  Report. Global Industry Analysts, Inc. 2020;September:367.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Jiang Y., Jacobs M., Bajaksouzian S. et al. Risk factors for microbial bioburden during daily wear of silicone hydrogel contact lenses. Eye Contact Lens. 2014;40:148–156. https://doi.org/10.1016/j.clae.2015.04.007</mixed-citation><mixed-citation xml:lang="en">Jiang Y., Jacobs M., Bajaksouzian S. et al. Risk factors for microbial bioburden during daily wear of silicone hydrogel contact lenses. Eye Contact Lens. 2014;40:148–156. https://doi.org/10.1016/j.clae.2015.04.007</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Dumbleton K., Woods C., Jones L. et al. Patient and practitioner compliance with silicone hydrogel and daily disposable lens replacement in the United States. Eye Contact Lens. 2009;35:164–171. https://doi.org/10.1097/ICL.0b013e3181ac4a8d</mixed-citation><mixed-citation xml:lang="en">Dumbleton K., Woods C., Jones L. et al.  Patient and practitioner compliance with silicone hydrogel and daily disposable lens replacement in the United States. Eye Contact Lens. 2009;35:164–171. https://doi.org/10.1097/ICL.0b013e3181ac4a8d</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Szczotka-Flynn L., Ahearn D.G., Barr J., Benjamin W.J., Kiang T., Nichols J.J., Schein O.D., Stone R.P., Winterton L. History, evolution, and evolving standards of contact lens care. Cont. Lens Anterior Eye. 2013;15(36(1)):4–8. https://doi.org/10.1016/S1367-0484(13)60003-X</mixed-citation><mixed-citation xml:lang="en">Szczotka-Flynn L., Ahearn D.G., Barr J., Benjamin W.J., Kiang T., Nichols J.J., Schein O.D., Stone R.P., Winterton L. History, evolution, and evolving standards of  contact lens care. Cont. Lens Anterior Eye. 2013;15(36(1)):4–8. https://doi.org/10.1016/S1367-0484(13)60003-X</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Zaki M., Pardo J. and Carracedo G. A review of international medical device regulations: Contact lenses and lens care solutions. Cont. Lens Anterior Eye. 2018;42(2):136–146. https://doi.org/10.1016/j.clae.2018.11.001</mixed-citation><mixed-citation xml:lang="en">Zaki M., Pardo J., and Carracedo G. A review of international medical device regulations: Contact lenses and lens care solutions. Cont. Lens Anterior Eye. 2018;42(2):136–146. https://doi.org/10.1016/j.clae.2018.11.001</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Morgan P.B., Efron N., Toshida H. et al An international analysis of contact lens compliance. Contact Lens Anterior Eye. 2011;34:223–228. https://doi.org/10.1016/j.clae.2011.08.001</mixed-citation><mixed-citation xml:lang="en">Morgan P.B., Efron N., Toshida H. et al An international analysis of contact lens compliance. Cont. Lens Anterior Eye. 2011;34:223–228. https://doi.org/10.1016/j.clae.2011.08.001</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Zhu H., Bandara M.B., Vijay A.K. et al. Importance of rub and rinse in multipurpose contact lens solution. Optom. Vis. Sci. 2011, Aug; 88(8):967–972. https://doi.org/10.1097/OPX.0b013e31821bf976</mixed-citation><mixed-citation xml:lang="en">Zhu H., Bandara M.B., Vijay A.K. et al. Importance of rub and rinse in multipurpose contact lens solution. Optom. Vis. Sci. 2011, Aug; 88(8):967–972. https://doi.org/10.1097/OPX.0b013e31821bf976</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Efron N., Brennan N.A., Bright F.V. et al. Contact lens care and ocular surface homeostasis. Cont. Lens Anterior Eye. 2013;15(36(1)):9–13. https://doi.org/10.1016/S1367-0484(13)60004-1</mixed-citation><mixed-citation xml:lang="en">Efron N., Brennan N.A., Bright F.V. et al.  Contact lens care and ocular surface homeostasis. Cont. Lens Anterior Eye. 2013;15(36(1)):9–13. https://doi.org/10.1016/S1367-0484(13)60004-1</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Carnt N., Hoffman J., Verma S. et al. Acanthamoeba Keratitis: Confimation of the UK outbreak and a prospective case control study identifying contributing risk factors. Br. J. Ophthalmol. 2018;102(12):1621–1628. https://doi.org/10.1136/bjophthalmol-2018-312544</mixed-citation><mixed-citation xml:lang="en">Carnt N., Hoffman J., Verma S. et al. Acanthamoeba Keratitis: Confimation of the UK outbreak and a prospective case control study identifying contributing risk factors. Br. J. Ophthalmol. 2018;102(12):1621–1628. https://doi.org/10.1136/bjophthalmol-2018-312544</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Hutter J., Green J., Eydelman M.B. Proposed silicone hydrogel contact lens grouping system for lens care product compatibility testing. Eye Contact Lens. 2012;38(6):358–362. https://doi.org/10.1097/ICL.0b013e318260c959</mixed-citation><mixed-citation xml:lang="en">Hutter J., Green J., Eydelman M.B. Proposed silicone hydrogel contact lens grouping system for lens care product compatibility testing. Eye Contact Lens. 2012;38(6):358–362. https://doi.org/10.1097/ICL.0b013e318260c959</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Wilcox M.D. Solutions for care of silicone hydrogel lenses. Eye Contact Lens. 2016;39(1):24–28. https://doi.org/10.1097/ICL.0b013e318275e0d9</mixed-citation><mixed-citation xml:lang="en">Wilcox M.D.  Solutions for care of silicone hydrogel lenses. Eye Contact Lens. 2016;39(1):24–28. https://doi.org/10.1097/ICL.0b013e318275e0d9</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Hughes R., Kilvington S. Comparison of hydrogen peroxide contact lens disinfection systems and solutions against Acanthamoeba polyphaga. Antimicrob. Agents and chemother. 2001;45:2038–2043. https://doi.org/10.1128/AAC.45.7.2038-2043.2001</mixed-citation><mixed-citation xml:lang="en">Hughes R., Kilvington S.  Comparison of hydrogen peroxide contact lens disinfection systems and solutions against Acanthamoeba polyphaga. Antimicrob. Agents and chemother. 2001;45:2038–2043. https://doi.org/10.1128/AAC.45.7.2038-2043.2001</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Nichols J.J., Chalmers R.L., Dumbleton K. et al. The Case for Using Peroxide Contact Lens Care Solutions: A Review. Eye Contact Lens. 2019;45(2):69–82. https://doi.org/10.1097/ICL.0000000000000542</mixed-citation><mixed-citation xml:lang="en">Nichols J.J., Chalmers R.L., Dumbleton K. et al. The Case for Using Peroxide Contact Lens Care Solutions: A Review. Eye Contact Lens. 2019;45(2):69–82. https://doi.org/10.1097/ICL.0000000000000542</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Bron A.J., Evans V.E., Smith J.A. Grading of corneal and conjunctival staining in the context of other dry eye tests. Cornea. 2003;22(7):640–650. https://doi.org/10.1097/00003226-200310000-00008</mixed-citation><mixed-citation xml:lang="en">Bron A.J., Evans V.E., Smith J.A. Grading of corneal and conjunctival staining in the context of other dry eye tests. Cornea. 2003;22(7):640–650. https://doi.org/10.1097/00003226-200310000-00008</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Rosenthal R.A., McAnally C.L., McNamee L.S. et al. Broad spectrum antimicrobial activity of a new multi-purpose disinfecting solution. CLAO J. 2000;26:120–126. PMID: 10946981</mixed-citation><mixed-citation xml:lang="en">Rosenthal R.A., McAnally C.L., McNamee L.S. et al.  Broad spectrum antimicrobial activity of a new multi-purpose disinfecting solution. CLAO J. 2000;26:120–126. PMID: 10946981</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">Shoff M.E., Lucas A.D., Phillips K.S. et al. The effect of contact lens materials on disinfection activity of polyquaternium-1 and myristamidopropyl dimethylamine multipurpose solution against Staphylococcus aureus. Eye Contact Lens. 2012;38:374–378. https://doi.org/10.1097/ICL.0b013e31826f0fdb</mixed-citation><mixed-citation xml:lang="en">Shoff M.E., Lucas A.D., Phillips K.S. et al. The effect of contact lens materials on disinfection activity of polyquaternium-1 and myristamidopropyl dimethylamine multipurpose solution against Staphylococcus aureus. Eye Contact Lens. 2012;38:374–378. https://doi.org/10.1097/ICL.0b013e31826f0fdb</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Lui A.C., Netto A.L., Silva C.B. et al. Antimicrobial effiacy assessment of multi-use solution to disinfect hydrophilic contact lens, in vitro. Arq. Bras. Oftalmol. 2009;72:626–630. https://doi.org/10.1590/s0004-27492009000500005</mixed-citation><mixed-citation xml:lang="en">Lui A.C., Netto A.L., Silva C.B. et al.  Antimicrobial effiacy assessment of multi-use solution to disinfect hydrophilic contact lens, in vitro. Arq. Bras. Oftalmol. 2009;72:626–630. https://doi.org/10.1590/s0004-27492009000500005</mixed-citation></citation-alternatives></ref><ref id="cit27"><label>27</label><citation-alternatives><mixed-citation xml:lang="ru">Lievens C.W., Cilimberg K.C. Contact lens care tips for patients: an optometrist’s perspective. Clin. Optom. (Auckl.) 2017;11(9):113–121. https://doi.org/10.2147/OPTO.S139651</mixed-citation><mixed-citation xml:lang="en">Lievens C.W., Cilimberg K.C. Contact lens care tips for patients: an optometrist’s perspective. Clin. Optom. (Auckl.) 2017;11(9):113–121. https://doi.org/10.2147/OPTO.S139651</mixed-citation></citation-alternatives></ref><ref id="cit28"><label>28</label><citation-alternatives><mixed-citation xml:lang="ru">Carnt N.A., Evans V.E., Naduvilath Th.J., Willcox M.D., Papas E.B., Frick K.D., Holden B.A. Contact lens-related adverse events and the silicone hydrogel lenses and daily wear caresystem used. Arch. Ophthalmol. 2009;127(12):1616–1623. https://doi.org/10.1001/archophthalmol.2009.313</mixed-citation><mixed-citation xml:lang="en">Carnt N.A., Evans V.E., Naduvilath Th.J., Willcox M.D.P., Papas E.B., Frick K.D., Holden B.A. Contact lens-related adverse events and the silicone hydrogel lenses and daily wear caresystem used. Arch. Ophthalmol. 2009;127(12):1616–1623. https://doi.org/10.1001/archophthalmol.2009.313</mixed-citation></citation-alternatives></ref><ref id="cit29"><label>29</label><citation-alternatives><mixed-citation xml:lang="ru">Codling C.E., Maillard J.Y., Russell A.D. Aspects of the antimicrobial mechanisms of action of a polyquaternium and an amidoamine. J. Antimicrob. Chemother. 2003;51:1153–1158. https://doi.org/10.1093/jac/dkg228</mixed-citation><mixed-citation xml:lang="en">Codling C.E., Maillard J.Y., Russell A.D. Aspects of the antimicrobial mechanisms of action of a polyquaternium and an amidoamine. J. Antimicrob. Chemother. 2003;51:1153–1158. https://doi.org/10.1093/jac/dkg228</mixed-citation></citation-alternatives></ref><ref id="cit30"><label>30</label><citation-alternatives><mixed-citation xml:lang="ru">Ganendren R., Widmer F., Singhal V. et al. In vitro antifungal activities of inhibitors of phospholipases from the fungal pathogen Cryptococcus neoformans. Antimicrob. Agents. Chemother. 2004;48:1561–1569. https://doi.org/10.1128/aac.48.5.1561–1569.2004</mixed-citation><mixed-citation xml:lang="en">Ganendren R., Widmer F., Singhal V. et al.  In vitro antifungal activities of inhibitors of phospholipases from the fungal pathogen Cryptococcus neoformans. Antimicrob. Agents Chemother. 2004;48:1561–1569. https://doi.org/10.1128/aac.48.5.1561–1569.2004</mixed-citation></citation-alternatives></ref><ref id="cit31"><label>31</label><citation-alternatives><mixed-citation xml:lang="ru">Berntsen D.A., Hickson-Curran S.B., Jones L.W. et al. Subjective Comfort and Physiology with Modern Contact Lens Care Products. Optom. Vision Science. 2016;93(8):809–819. https://doi.org/10.1097/OPX.0000000000000901</mixed-citation><mixed-citation xml:lang="en">Berntsen D.A., Hickson-Curran S.B., Jones L.W. et al. Subjective Comfort and Physiology with Modern Contact Lens Care Products. Optom. Vision Science. 2016;93(8):809–819. https://doi.org/10.1097/OPX.0000000000000901</mixed-citation></citation-alternatives></ref><ref id="cit32"><label>32</label><citation-alternatives><mixed-citation xml:lang="ru">Tran V.B., Sung Y.S., Copley K. et al. Effects of aqueous polymeric surfactants on silicone-hydrogel soft- contact-lens wettability and bacterial adhesion of Pseudomonas aeruginosa. Cont. Lens Ant. Eye. 2012;35:155–162. https://doi.org/10.1016/j.clae.2012.02.006</mixed-citation><mixed-citation xml:lang="en">Tran V.B., Sung Y.S., Copley K. et al. Effects of aqueous polymeric surfactants on silicone-hydrogel soft- contact-lens wettability and bacterial adhesion of Pseudomonas aeruginosa. Cont. Lens Anterior Eye. 2012;35:155–162. https://doi.org/10.1016/j.clae.2012.02.006</mixed-citation></citation-alternatives></ref><ref id="cit33"><label>33</label><citation-alternatives><mixed-citation xml:lang="ru">Jones L., Jones D., Houlford M. Clinical comparison of three polyhexanide-preserved multi-purpose contact lens solutions. Cont. Lens Ant. Eye. 1997;20:23–30. https://doi.org/10.1016/s1367-0484(97)80032-x</mixed-citation><mixed-citation xml:lang="en">Jones L., Jones D., Houlford M. Clinical comparison of three polyhexanide-preserved multi-purpose contact lens solutions. Cont. Lens Anerior Eye. 1997;20:23–30. https://doi.org/10.1016/s1367-0484(97)80032-x</mixed-citation></citation-alternatives></ref><ref id="cit34"><label>34</label><citation-alternatives><mixed-citation xml:lang="ru">Аветисов С.Э., Абрамова Н.Д., Гоголева Н.Е., Гусев О.А., Митичкина Т.С., Новиков И.А., Суббот А. М., Шагимарданова Е.И. Рациональная стратегия изучения микробиома глазной поверхности пользователей жестких контактных линз методом метабаркодинга по гену 16S рРНК. Вестн. офтальм. 2020;136(3):3–9. https://doi.org/10.17116/oftalma20201360313</mixed-citation><mixed-citation xml:lang="en">Avetisov S.E. , Abramova N.D., Gogoleva N.E , Gusev O.A., Mitichkina T.S., Novikov I.A., Subbot A.M., Shagimardanova E.I. Rational strategy for studying microbiome of the ocular surface of people using hard contact lenses by method of 16S rRNA gene metabarcoding. Vestn. Oftalmol. 2020;136(3):3–9. https://doi.org/10.17116/oftalma20201360313</mixed-citation></citation-alternatives></ref><ref id="cit35"><label>35</label><citation-alternatives><mixed-citation xml:lang="ru">Shin H., Price K., Albert L., Dodick J., Park L., Dominguez-Bello M.G. Changes in the Eye Microbiota Associated with Contact Lens Wearing. mBio. 2016;7(2). https://doi.org/10.1128/mBio.00198-16</mixed-citation><mixed-citation xml:lang="en">Shin H., Price K., Albert L., Dodick J., Park L., Dominguez-Bello M.G. Changes in the Eye Microbiota Associated with Contact Lens Wearing. mBio. 2016;7(2). https://doi.org/10.1128/mBio.00198-16</mixed-citation></citation-alternatives></ref><ref id="cit36"><label>36</label><citation-alternatives><mixed-citation xml:lang="ru">Hotta F., Eguchi H., Nakayama-Imaohji H., Kuwahara T., Tada A., Yagi H., Shimomura Y., Kusaka Sh. Microbiome analysis of contact lens care solutions and tear flids of contact lens wearers: Possible involvement of streptococcal antigens in allergic symptoms related to contact lens wear. Int. J. Mol. Med. 2020;46(4):1367–1376. https://doi.org/10.3892/ijmm.2020.4678</mixed-citation><mixed-citation xml:lang="en">Hotta F., Eguchi H.,  Nakayama-Imaohji H., Kuwahara T., Tada A., Yagi H., Shimomura Y., Kusaka Sh. Microbiome analysis of contact lens care solutions and tear flids of contact lens wearers: Possible involvement of streptococcal antigens in allergic symptoms related to contact lens wear. Int. J. Mol. Med. 2020;46(4):1367–1376. https://doi.org/10.3892/ijmm.2020.4678</mixed-citation></citation-alternatives></ref><ref id="cit37"><label>37</label><citation-alternatives><mixed-citation xml:lang="ru">Andrasko G., Ryen K. Corneal staining and comfort observed with traditional and silicone hydrogel lenses and multipurpose solution combinations. Optometry 2008;79:444–454. doi:10.1016/j.optm.2008.04.097</mixed-citation><mixed-citation xml:lang="en">Andrasko G., Ryen K. Corneal staining and comfort observed with traditional and silicone hydrogel lenses and multipurpose solution combinations. Optometry 2008;79:444–454. doi:10.1016/j.optm.2008.04.097</mixed-citation></citation-alternatives></ref><ref id="cit38"><label>38</label><citation-alternatives><mixed-citation xml:lang="ru">Jones L., MacDougall N., Sorbara L.G. Asymptomatic corneal staining associated with the use of balaficon silicone-hydrogel contact lenses disinfected with a polyaminopropyl biguanide-preserved care regimen. Optom. Vis. Sci. 2002;79:753–761. https://doi.org/10.1097/00006324-200212000-00007</mixed-citation><mixed-citation xml:lang="en">Jones L., MacDougall N., Sorbara L.G. Asymptomatic corneal staining associated with the use of balaficon silicone-hydrogel contact lenses disinfected with a polyaminopropyl biguanide-preserved care regimen. Optom. Vis. Sci. 2002;79:753–761. https://doi.org/10.1097/00006324-200212000-00007</mixed-citation></citation-alternatives></ref><ref id="cit39"><label>39</label><citation-alternatives><mixed-citation xml:lang="ru">Zigler L., Cedrone R., Evans D. et al. Clinical evaluation of silicone hydrogel lens wear with a new multipurpose disinfection care product. Eye Contact Lens. 2007;33:236–243. https://doi.org/10.1097/ICL.0b013e318030c959</mixed-citation><mixed-citation xml:lang="en">Zigler L., Cedrone R., Evans D. et al. Clinical evaluation of silicone hydrogel lens wear with a new multipurpose disinfection care product. Eye Contact Lens. 2007;33:236–243. https://doi.org/10.1097/ICL.0b013e318030c959</mixed-citation></citation-alternatives></ref><ref id="cit40"><label>40</label><citation-alternatives><mixed-citation xml:lang="ru">Zhang X., Marchetti C., Lee J., Sun Y., Debanne S., Jiang Y., Kern J., Harrod M., Benetz B.A., Pearlman E., Szczotka-Flynn L. The impact of lens care solutions on corneal epithelial changes duringdaily silicone hydrogel contact lens wear as measured by in vivoconfocal microscopy Cont. Lens Anterior Eye. 2016. (BCLA. 2017.). https://doi.org/10.1016/j.clae.2016.11.006</mixed-citation><mixed-citation xml:lang="en">Zhang X., Marchetti C., Lee J., Sun Y., Debanne S., Jiang Y., Kern J., Harrod M., Benetz B.A. Pearlmana E, Szczotka-Flynn L. The impact of lens care solutions on corneal epithelial changes duringdaily silicone hydrogel contact lens wear as measured by in vivoconfocal microscopy Cont. Lens Anterior Eye. 2016. (BCLA. 2017.). https://doi.org/10.1016/j.clae.2016.11.006</mixed-citation></citation-alternatives></ref><ref id="cit41"><label>41</label><citation-alternatives><mixed-citation xml:lang="ru">Keir N., Woods C.A., Dumbleton K. et al. Clinical performance of different care systems with silicone hydrogel contact lenses. Cont. Lens Ant. Eye. 2010;33:189–195. https://doi.org/10.1016/j.clae.2010.01.006</mixed-citation><mixed-citation xml:lang="en">Keir N., Woods C.A., Dumbleton K. et al. Clinical performance of different care systems with silicone hydrogel contact lenses. Cont. Lens Anterior. Eye. 2010;33:189–195. https://doi.org/10.1016/j.clae.2010.01.006</mixed-citation></citation-alternatives></ref><ref id="cit42"><label>42</label><citation-alternatives><mixed-citation xml:lang="ru">Ramamoorthy P., Sinnott L.T., Nichols J.J. Treatment, material, care, and patient-related factors in contact lens-related dry eye. Optom. Vis. Sci. 2008;85:764–772. https://doi.org/10.1097/OPX.0b013e318181a91f</mixed-citation><mixed-citation xml:lang="en">Ramamoorthy P., Sinnott L.T., Nichols J.J. Treatment, material, care, and patient-related factors in contact lens-related dry eye. Optom. Vis. Sci. 2008;85:764–772. https://doi.org/10.1097/OPX.0b013e318181a91f</mixed-citation></citation-alternatives></ref><ref id="cit43"><label>43</label><citation-alternatives><mixed-citation xml:lang="ru">Zhu H., Stapleton F. Biocidal effiacy of silver-impregnated contact lens storage cases in vitro. Jaya Dantam Invest. Ophthalmol. Vis. Sci. 2011;5(52(1)):51–57. https://doi.org/10.1167/iovs.09-4809</mixed-citation><mixed-citation xml:lang="en">Zhu H., Stapleton F. Biocidal effiacy of silver-impregnated contact lens storage cases in vitro. Jaya Dantam Invest. Ophthalmol. Vis. Sci.  2011;5(52(1)):51–57. https://doi.org/10.1167/iovs.09-4809</mixed-citation></citation-alternatives></ref><ref id="cit44"><label>44</label><citation-alternatives><mixed-citation xml:lang="ru">Jones L., Walsh K., Willcox M., Morgan P., Nichols J. The COVID-19 pandemic: important considerations for contact lens practitioners. Cont. Lens Anterior Eye. 2020;43(3):196–203. PMCID: PMC7129028. https://doi.org/10.1016/j.clae.2020.03.012</mixed-citation><mixed-citation xml:lang="en">Jones L., Walsh K., Willcox M., Morgan P., Nichols J. The COVID-19 pandemic: important considerations for contact lens practitioners. Cont. Lens Anterior Eye. 2020;43(3):196–203.  PMCID:  PMC7129028. https://doi.org/10.1016/j.clae.2020.03.012</mixed-citation></citation-alternatives></ref><ref id="cit45"><label>45</label><citation-alternatives><mixed-citation xml:lang="ru">American Academy of Optometry. Contact lens wear &amp; coronavirus: do’s &amp; don’ts. 2020;April.(9). https://www.aaopt.org/docs/covid-19/aao-011-contact-lens-wear-coronavirus. pdf?sfvrsn=4d10ad23_0</mixed-citation><mixed-citation xml:lang="en">American Academy of Optometry. Contact lens wear &amp; coronavirus: do’s &amp; don’ts. 2020;April.(9). https://www.aaopt.org/docs/covid-19/aao-011-contact-lens-wear-coronavirus. pdf?sfvrsn=4d10ad23_0</mixed-citation></citation-alternatives></ref><ref id="cit46"><label>46</label><citation-alternatives><mixed-citation xml:lang="ru">Napoli P.E., Nioi M., d’Aloja E., Fossarello M. The ocular surface and the coronavirus disease 2019: does a dual “ocular route” exist? J. Clin. Med. 2020;9(5):1269. https://doi.org/10.3390/jcm9051269. PMCID: PMC7287662</mixed-citation><mixed-citation xml:lang="en">Napoli P.E., Nioi M., d’Aloja E., Fossarello M. The ocular surface and the coronavirus disease 2019: does a dual “ocular route” exist?  J. Clin. Med.  2020;9(5):1269.  https://doi.org/10.3390/jcm9051269. PMCID:  PMC7287662</mixed-citation></citation-alternatives></ref><ref id="cit47"><label>47</label><citation-alternatives><mixed-citation xml:lang="ru">Zeri F., Naroo S.A. Contact lens practice in the time of COVID-19. Cont. Lens Anterior Eye. 2020;43(3):193–195. https://doi.org/10.1016/j.clae.2020.03.007. PMCID:PMC7270367</mixed-citation><mixed-citation xml:lang="en">Zeri F., Naroo S.A. Contact lens practice in the time of COVID-19. Cont. Lens Anterior Eye.  2020;43(3):193–195. https://doi.org/10.1016/j.clae.2020.03.007. PMCID: PMC7270367</mixed-citation></citation-alternatives></ref><ref id="cit48"><label>48</label><citation-alternatives><mixed-citation xml:lang="ru">Bakkara M., Eman A. Alzghoula. Assessment of contact lens wearers’ attitude toward contact lens wear and care during Coronavirus Disease 2019 (COVID-19) pandemic: A cross-sectional online survey. May, Cont. Lens Anterior Eye. 2021;Jan.14. https://doi.org/10.1016/j.clae.2021.01.005.PMCID: PMC7832052</mixed-citation><mixed-citation xml:lang="en">Bakkara M., Eman A. Alzghoula. Assessment of contact lens wearers’ attitude toward contact lens wear and care during Coronavirus Disease 2019 (COVID-19) pandemic: A  cross-sectional online survey. May, Cont. Lens Anterior Eye. 2021;Jan.14. https://doi.org/10.1016/j.clae.2021.01.005.PMCID:  PMC7832052</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
